1,000 L/day · 25 L Mixed Bed · 12 L Pressure Tank

Mixed Bed Pure Water System: 1,000 Litres a Day with 25 Litres of Resin

The Mixed Bed Pure Water System is a pure water system that combines a 5 × 100 GPD reverse osmosis unit with 25 litres of mixed bed pure water resin in a 10″ × 35″ tank. In place of the 5 litres of resin in the standard model, five times the volume of mixed bed resin is used; the ions remaining in the water after reverse osmosis are captured in this large column. The system produces up to 1,000 litres of pure water in 24 hours, and a 12 litre pressure tank keeps water ready for short draw-offs.

Daily Capacity
1,000 Litres
Pure Water Resin (DI)
25 L Mixed Bed
Pressure Tank
12 Litres

01Problem & Solution

Resin Volume Decides How Long Purity Lasts

Problem

A Small Resin Bed Saturates Quickly

Reverse osmosis treats water to a large extent; laboratory and precision manufacturing work, however, calls for lower conductivity. The resin that takes on this final step becomes saturated over time with the ions it captures. If the resin volume is small and daily use is high, saturation comes early; the resin has to be renewed often and keeping track of purity becomes harder.

Solution

25 Litres of Mixed Bed in a 10″ × 35″ Tank

In place of the 5 litres of resin in the standard model’s 8″ × 17″ tank, the Mixed Bed Pure Water System uses 25 litres of mixed bed resin in a 10″ × 35″ tank about 1 metre tall. With the same feed water and the same use, the resin lasts longer. The reverse osmosis unit stays as in the standard model; the set comes with a 12 litre pressure tank.

02Key Features

The Same Reverse Osmosis, Five Times the Resin

The Mixed Bed Pure Water System keeps the reverse osmosis capacity of the standard model, enlarges the pure water resin and comes with a 12 litre pressure tank.

5 × 100 GPD Membranes

Five 100 GPD membranes work together; the reverse osmosis section, 500 GPD in total, produces up to 1,000 litres of water in 24 hours.

25 Litre Mixed Bed Resin

The pure water stage, in which cation and anion resins sit together in a mixed bed, captures the ions remaining in the water after reverse osmosis.

10″ × 35″ Resin Tank

The tank, about 1 metre tall, holds the 25 litres of resin in a single column; the pure water stage is controlled by a manual valve.

12 Litre Pressure Tank

It holds part of the pure water produced under pressure and delivers it ready to the tap for short draw-offs.

Three 20 inch Pre-Filters

The pre-filters in the blue 20 inch filter housings protect the membranes by capturing sediment, chlorine and coarse contaminants.

Pump and Pressure Gauge

The booster pump raises the water to the pressure the membranes need; system pressure is monitored on the pressure gauge.

03Technical Specifications

Mixed Bed Pure Water System: Technical Details

FeatureValueWhat it does
System TypeReverse Osmosis + Mixed Bed (RO + DI)The main problem the system solves. Pick the wrong type and the water does not improve.
Daily Capacity1,000 Litres (in 24 Hours)How much water it can treat in a day. It should be at least 1.5 times your daily use.
RO Membrane5 × 100 GPD (500 GPD)The reverse osmosis membrane. This is the part that decides how pure the water is.
Pure Water Resin (DI)25 L Mixed Bed (Mixbed)
Resin Tank10" × 35" · About 1 m
Resin ControlManual Valve
Pressure Tank12 Litres
Pre-Filter3 × 20 inch Filter Housings
PumpBooster PumpThe unit that provides pressure. It is needed where mains pressure is low.
MonitoringPressure GaugeThe user panel. Filter life and fault warnings are read here.
RO FrameVertical Black Metal

04Applications

Where Is It Used?

The Mixed Bed Pure Water System suits laboratories and businesses that use up to 1,000 litres of low-conductivity water a day.

LaboratoriesCosmetics ManufacturingBattery and Accumulator WaterElectronics and Optics WashingChemical and Plating LinesFeeding Laboratory EquipmentGlass and Surface RinsingMedium-Scale Production

05How It Works

How Does the Mixed Bed Pure Water System Work?

In the Mixed Bed Pure Water System, the water passes through five stages. Purity is usually monitored by conductivity; the US Geological Survey’s (USGS) page on conductivity explains that conductivity falls as the ions dissolved in the water decrease.

  1. Pre-Filtration

    Raw water passes through three 20 inch pre-filters; sediment, chlorine and coarse contaminants are captured and the membranes are protected.

  2. Pressurisation

    The booster pump raises the water to the working pressure of the membranes; the pressure is monitored on the pressure gauge.

  3. Reverse Osmosis

    The water passes through the 5 × 100 GPD membranes; most of the dissolved salts are discharged with the reject water.

  4. 25 Litre Mixed Bed Column

    The water from reverse osmosis passes through the mixed bed resin in the 10″ × 35″ tank; the cation resin captures positively charged ions, the anion resin negatively charged ones, and purity rises.

  5. 12 Litre Pressure Tank

    The pure water collects in the small pressure tank; when a tap or line is opened, tank pressure sends it to the point of use. For larger draw-offs, the water can also be taken into a separate storage tank.

06Making the Right Choice

Is the Mixed Bed Pure Water System Right for You?

When choosing the Mixed Bed Pure Water System, daily consumption, peak draw-off, feed water and target purity are assessed together.

Daily Consumption

If the daily requirement exceeds 1,000 litres, a higher-capacity system is needed; one can be engineered to suit.

Peak Draw-Off

The 12 litre pressure tank is for short draw-offs. If a lot of water is drawn in a short time, a larger pressure tank or a separate storage tank should be planned.

Feed Water Hardness

In hard, limescale-laden water, adding water softening pre-treatment ahead of the unit should be considered to protect the membranes.

Target Purity

The conductivity value the application requires determines how often the resin must be renewed; regular measurement is recommended.

07Maintenance and Use

Maintenance Notes That Preserve Purity

With regular maintenance, the Mixed Bed Pure Water System keeps delivering water of the same purity.

  • Change the pre-filters periodically according to the condition of the water; a blocked filter strains the membranes and the pump.
  • Measure the conductivity of the pure water regularly; when the reading starts to rise, the mixed bed resin is saturated and must be renewed.
  • Watch the pressure gauge; an unusual drop in pressure can point to a blocked filter or a membrane problem.
  • Have the air pressure of the pressure tank checked against the manufacturer’s values while the tank is empty.
  • If the unit will not be used for a long time, drain the water in the tank; when restarting, discard the first water produced.

08Frequently Asked Questions

Common Questions

What does the Mixed Bed Pure Water System do?
It produces pure water by stripping the water of its ions with reverse osmosis and 25 litres of mixed bed resin. It is used in work that needs low conductivity, such as laboratories, cosmetics, battery water and precision manufacturing.
How much pure water does it produce a day?
The Mixed Bed Pure Water System produces up to 1,000 litres of pure water in 24 hours. Real output varies with incoming water quality, temperature and pressure.
How does it differ from the standard model?
The reverse osmosis section and the capacity are the same as in the standard model; the set comes with a 12 litre pressure tank. The pure water resin goes up from 5 litres to 25 litres and sits in a 10″ × 35″ tank instead of an 8″ × 17″ one.
When is the mixed bed resin renewed?
The renewal interval depends on the ionic load of the feed water and the amount of water used, so a fixed period cannot be given. The resin is renewed when the conductivity of the pure water rises above the target value.
Can pure water be drunk?
Because it contains no minerals, pure water is not intended as drinking water; it is used in laboratory, production and technical work.
Is installation included in the price?
Installation and commissioning of the unit are the customer’s responsibility; on request, they are carried out by Water Point for a fee. Paid installation is provided only for units purchased from Water Point.
What does the warranty cover?
Units, valves, pumps and tanks carry a 2-year warranty and taps a 1-year warranty. Filters, membranes, resin and salt are consumables and are therefore outside warranty cover.

Reviews

There are no reviews yet.

Be the first to review “Mixed Bed Pure Water System, 1,000 L/day – 25 L Resin, 12 L Pressure Tank”

Questions & Answers

Questions asked about this product

Questions on compatibility, capacity and installation are answered by our technical team. The answers stay public — so the next person with the same question can see them too.

No questions have been published for this product yet. You can be the first to ask.

Ask a question about this product

Your email address will not be published. Questions are reviewed by our technical team and published together with the answer.

Delivery

Confirmed when the order is placed

The delivery time is confirmed to you when your order is approved. This product is heavy and bulky, so it is shipped by freight; freight costs within Türkiye are covered by us.

Installation and commissioning

Installation is a service · plumbing is the customer’s responsibility

The system is delivered ready to install; it only needs to be connected to the inlet and outlet lines. If valve setup is required, we provide free support over a video call. Installation and commissioning fall under our service work and are subject to a service fee. Plumbing labour and any pipes, valves and fittings are not included in the price; these items are the customer’s responsibility.

Warranty

2 years · manufacturer

This product is covered by a 2-year manufacturer warranty. During the warranty period, labour and parts are free for faults arising from manufacture. Consumables such as filters, membranes and resin are outside warranty cover — they are replaced when their service life ends; they do not fail.

Withdrawal and returns

Distance sales agreement

The right of withdrawal and the return terms are set out in detail in the distance sales agreement. Systems that have been installed and commissioned, and made-to-order products, are outside its scope.

Cancellation and return terms

How can we help?

Two different requests, two different forms.

The two forms ask different things: if we are building a new system we ask about your water and capacity; if your existing system needs service we ask for its brand and a photo.

Not sure? Call us and let’s work it out together: 0850 304 95 25

₺82,276.26 VAT included
Add to Cart