Semi-Industrial Pure Water System

144,783.90

VAT included · Made to order · Free shipping in Türkiye

Installation is a service · plumbing is the customer’s responsibility

Free Shipping Across Türkiye
Lead Time Confirmed when the order is placed
2-Year Warranty Misuse is not covered.
Order by Phone 0850 304 95 25
SKU
WP-SS-010
Category
, , , ,

Which capacity is enough for you? Let us find the unit that suits you best in six questions.

Semi-Industrial · RO + Mixed Bed + UV

Near-Zero Conductivity with the Semi-Industrial Pure Water System

The Semi-Industrial Pure Water System is a professional pure water plant that combines pre-treatment softening, reverse osmosis, mixed bed resin and ultraviolet stages to bring the conductivity of water down to near zero (0 µS). With a capacity of 2.5 tonnes a day, it is designed for mid-scale laboratory, production and industrial applications.

Capacity
2.5 Tonnes a Day
Conductivity
Near Zero (0 µS)
Stages
Softening / RO / Mixed Bed / UV

01Problem & Solution

The Need for Ultra-Pure Water at Mid Scale

Problem

One Stage Is Not Enough

In mid-scale laboratory and production processes, reverse osmosis on its own does not always give the purity wanted. The low levels of ions left in the water cause residues and measurement errors in sensitive processes.

Solution

A Four-Stage Combination

After softening and reverse osmosis, the Semi-Industrial Pure Water System removes the remaining ions with mixed bed resin as well. The ultraviolet stage at the tank outlet provides extra microbiological safety, and conductivity falls to near zero.

02Key Features

Pure, Steady, Professional

The Semi-Industrial Pure Water System delivers high purity steadily for mid-scale production.

Pre-Treatment Softening

It takes the hardness out of the water, protecting the membrane and raising the efficiency of the system.

Reverse Osmosis Stage

It separates most of the dissolved salts, heavy metals and contaminants from the water.

25 Litres of Mixed Bed Resin

The mixed bed resin holds back the ions left after RO as well, bringing conductivity down to the lowest level.

UV Protection at the Tank Outlet

The ultraviolet stage breaks down the structure of microorganisms and provides extra microbiological safety.

2,5 Tonnes a Day

It offers steady output suited to mid-scale laboratory, production and industrial applications.

Near-Zero Conductivity

Staged treatment brings the conductivity of the water down to near zero (0 µS).

03Technical Specifications

System Details

FeatureValueWhat it does
System TypeSemi-Industrial Pure Water SystemThe main problem the system solves. Pick the wrong type and the water does not improve.
StagesSoftening + RO + Mixed Bed + UVThe order of the stages. It runs from coarse sediment towards fine treatment.
Daily Capacity2,5 TonnesHow much water it can treat in a day. It should be at least 1.5 times your daily use.
Mixed Bed Resin25 LitresThe material that holds back limescale. The more of it, the greater the softening capacity.
ConductivityNear Zero (0 µS)A measure of the dissolved matter in the water. The closer to zero, the purer it is.
UseLaboratory / Production / IndustryWhat setting it was designed for. A domestic unit will not carry a commercial load.

04Applications

Where Is It Used?

The Semi-Industrial Pure Water System is used wherever high-purity water is needed at mid scale.

  • Laboratories
  • Pharmaceutical & Medical Manufacturing
  • Electronics Manufacturing
  • The Cosmetics Industry
  • Glass & Surface Washing
  • Boiler & Steam Feed
  • Mid-Scale Production Plants
  • R&D & Analysis Centres

05How It Works

How Does the Semi-Industrial Pure Water System Work?

  1. Pre-Treatment & Softening

    After the sediment and carbon stages, the raw water passes through softening; the hardness is taken out and the membrane protected.

  2. Reverse Osmosis

    The membrane separates most of the dissolved salts and contaminants, bringing the water down to low conductivity.

  3. Mixed Bed Polishing

    The mixed bed resin holds back the cations and anions left after RO, bringing conductivity close to zero.

  4. The Ultraviolet Stage

    The UV at the tank outlet breaks down the structure of microorganisms and provides extra microbiological safety.

  5. Pure Water Is Delivered to Use

    Pure water with conductivity close to zero is taken into the tank or fed directly into the process for use.

06Making the Right Choice

What Decides the Right System

When choosing the Semi-Industrial Pure Water System, the purity target, capacity and feed water should be assessed.

Purity Target

The conductivity level your application requires determines the mixed bed and the stages used.

Daily Capacity

2.5 tonnes is the capacity of this model; different capacities are engineered for higher needs.

Feed Water

The hardness and TDS of the raw water affect the pre-treatment required and the life of the resin.

Continuity & Space

Uninterrupted production and the placement of the tanks are taken into account in the build and sizing of the system.

07Maintenance and Use

Notes That Preserve Purity

  • Conductivity should be monitored continuously; when the value begins to rise, it means the mixed bed resin is saturated.
  • The mixed bed resin is generally replaced with new resin every 6–12 months, depending on how heavily it is used.
  • The softening salt, pre-filter and membrane should be maintained on time; that protects the life of the mixed bed and the steadiness of the purity.
  • The UV lamp should be renewed at the interval recommended by the manufacturer to stay effective; pure water should not be used as drinking water.

08Frequently Asked Questions

Common Questions

What does the Semi-Industrial Pure Water System do?
It combines softening, reverse osmosis, mixed bed resin and ultraviolet stages to bring the conductivity of water down to near zero. With a capacity of 2.5 tonnes a day, it produces high-purity water for mid-scale laboratory, production and industrial applications.
What does the mixed bed resin do?
The mixed bed resin holds back the cation and anion ions left after reverse osmosis as well. This final polishing stage brings conductivity down to the lowest level, giving ultra-pure water.
What does the UV stage provide?
The ultraviolet stage at the tank outlet breaks down the structure of microorganisms and provides extra microbiological safety. It does so without chemicals and without affecting the purity of the water.
Can pure water be drunk?
Pure water is not recommended as drinking water because it contains no minerals. It is used for technical and industrial processes and sensitive production applications.
Is a higher capacity possible?
Yes. This model produces 2.5 tonnes a day; for higher capacity needs the system can be engineered at different capacities according to the water analysis and consumption.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Questions & Answers

Questions asked about this product

Questions on compatibility, capacity and installation are answered by our technical team. The answers stay public — so the next person with the same question can see them too.

No questions have been published for this product yet. You can be the first to ask.

Ask a question about this product

Your email address will not be published. Questions are reviewed by our technical team and published together with the answer.

Delivery

Confirmed when the order is placed

This product is not held in stock; it is supplied to order and the lead time is confirmed to you when the order is approved. Shipping is free anywhere in Türkiye.

Installation and commissioning

Installation is a service · plumbing is the customer’s responsibility

The system is delivered ready to install; it only needs to be connected to the inlet and outlet lines. If valve setup is required, we provide free support over a video call. Installation and commissioning fall under our service work and are subject to a service fee. Plumbing labour and any pipes, valves and fittings are not included in the price; these items are the customer’s responsibility.

Warranty

2 years · manufacturer

The system is covered by a 2-year manufacturer warranty. During the warranty period, labour and parts are free for faults arising from manufacture or installation. Consumables such as filters, membranes and resin are outside warranty cover — they are replaced when their service life ends; they do not fail.

Withdrawal and returns

Distance sales agreement

The right of withdrawal and the return terms are set out in detail in the distance sales agreement. Systems that have been installed and commissioned, and made-to-order products, are outside its scope.

Cancellation and return terms

How can we help?

Two different requests, two different forms.

The two forms ask different things: if we are building a new system we ask about your water and capacity; if your existing system needs service we ask for its brand and a photo.

Not sure? Call us and let’s work it out together: 0850 304 95 25