Ultraviolet Unit

31,369.85

VAT included · In stock · Free shipping

Is this system right for you? Let’s decide together

Installation is a service · plumbing is the customer’s responsibility

Free Shipping Across Türkiye
Fast Delivery Across Türkiye · 1–3 business days
2-Year Warranty Misuse is not covered.
Order by Phone 0850 304 95 25
SKU
WP-UV-003
Category

Which capacity is enough for you? Let us find the unit that suits you best in six questions.

Ultraviolet · Final Treatment Stage

Chemical-Free Microbiological Safety with the Ultraviolet Unit

The Ultraviolet Unit applies ultraviolet light to the water passing through it, breaking down the structure of the bacteria, viruses and microorganisms in the water and rendering them inactive. It gives microbiological safety without any chemicals and without changing the taste or structure of the water.

Method
Ultraviolet Light
Chemicals
Not Used
Position
Final Stage

01Problem & Solution

Microbiological Risk in Water

Problem

Filters Do Not Hold Microorganisms

Sediment and carbon filters improve the taste and clarity of water but are not enough against microorganisms such as bacteria and viruses. Well water and systems with storage tanks in particular need microbiological safety at the final point.

Solution

Rendered Inactive by Ultraviolet Light

By exposing water to ultraviolet light inside a stainless chamber, the Ultraviolet Unit breaks down the structure of microorganisms and stops them multiplying. It works without chemicals and leaves no odour or taste in the water.

02Key Features

Chemical-Free, Effective, Practical

The Ultraviolet Unit is a practical, dependable solution for final-stage microbiological safety on domestic and commercial water.

Chemical-Free Operation

It gives microbiological treatment with ultraviolet light alone, adding no chemicals whatsoever to the water.

Preserves Taste and Structure

It offers microbiological safety without changing the taste, odour or chemical structure of the water.

Stainless Chamber

The stainless steel body gives a hygienic, long-life treatment chamber.

Immediate Effect

Water is exposed to the light as it passes through the chamber; it is rendered inactive within seconds.

Easy Maintenance

Performance is maintained with a lamp change usually once a year; it is simple to use.

Fits as a Final Stage

It is easily integrated into the treatment line as the final stage after filters and reverse osmosis.

Product Video

Take a Closer Look at the Unit

YouTube video

03Technical Specifications

System Details

FeatureValueWhat it does
MethodUltraviolet LightThe physical or chemical principle behind the treatment.
BodyStainless SteelThe outer body material. Stainless steel means high pressure and a long life.
ComponentsBody · Lamp · Quartz · Adaptor
ChemicalsNot Required
Lamp ChangeOnce a Year (~9,000 Hours)The regular maintenance load. If filters are not changed on time, performance drops.
UseDomestic / CommercialWhat setting it was designed for. A domestic unit will not carry a commercial load.
Weight5 kgProduct weight. For wall mounting, the supporting surface is chosen accordingly.
Dimensions15 × 100 × 20 cmThe outer dimensions of the unit. The cabinet or plant room has to be wider than this.

04Applications

Where Is It Used?

The Ultraviolet Unit is used as a final stage on domestic and commercial water where microbiological safety is wanted.

  • Homes
  • Workplaces & Offices
  • Well Water Lines
  • Systems with Storage Tanks
  • Cafés & Restaurants
  • Final Stage After RO
  • Drinking & Utility Water
  • Villa & Estate Drinking Water

05How It Works

How Does the Ultraviolet Unit Work?

  1. Water Enters the Chamber

    Clear water is directed around the quartz-sleeved ultraviolet lamp inside the stainless steel chamber.

  2. It Is Exposed to Ultraviolet Light

    The water is exposed to the ultraviolet light emitted by the lamp; the light reaches the cell structure of the microorganisms.

  3. The Structure Breaks Down

    The light breaks down the genetic structure of bacteria, viruses and microorganisms and stops them multiplying.

  4. Chemical-Free Treatment

    The process happens with light alone; no chemicals are added to the water and taste and odour do not change.

  5. Safe Water Out

    The water, now microbiologically safe, is delivered to the point of use.

06Making the Right Choice

What Decides the Right Unit

When choosing the Ultraviolet Unit, the water flow and the clarity of the inlet water must be assessed correctly.

Water Flow Rate

Hourly water consumption determines the lamp power (watts) and unit capacity required.

Inlet Water Clarity

Turbid water reduces the effectiveness of the light; sediment and carbon filtration is needed beforehand.

Installation Position

The unit is usually positioned at the final stage of treatment, close to the point of use.

Maintenance Plan

Lamp and quartz sleeve maintenance should be planned; access to a spare lamp and adaptor matters.

07Maintenance and Use

Notes That Keep It Performing

  • The lamp loses efficiency over time; even while it goes on emitting light, changing it once a year (around 9,000 hours) is generally recommended.
  • The quartz sleeve can pick up limescale and sediment over time; cleaning it periodically preserves the transmission of the light.
  • The unit should be kept permanently powered; switching it on and off frequently can shorten lamp life.
  • The Ultraviolet Unit only provides microbiological safety; salts, limescale or sediment call for RO, softening and filters as well.

08Frequently Asked Questions

Common Questions

What does the Ultraviolet Unit do?
By applying ultraviolet light to the water, it breaks down the structure of the bacteria, viruses and microorganisms in it and renders them inactive. It gives the water microbiological safety at the final stage without chemicals, and does not change its taste or structure.
Does it add chemicals or change the taste?
No. Ultraviolet light adds no chemicals to the water and does not change its structure. It therefore leaves no odour, taste or residue; it is a chemical-free treatment method.
When is the lamp changed?
Even while it goes on emitting light, the lamp loses treatment efficiency over time. Changing it after roughly 9,000 hours, that is once a year, is generally recommended.
Does it work on turbid water?
The water must be clear for ultraviolet light to be effective. On turbid or sediment-laden water, sediment and carbon filtration before the unit is recommended.
Is it enough on its own?
The Ultraviolet Unit only provides microbiological safety; it does not remove salinity, limescale or sediment from water. For those needs it is used as a final stage together with reverse osmosis, softening and filter stages.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Questions & Answers

Questions asked about this product

Questions on compatibility, capacity and installation are answered by our technical team. The answers stay public — so the next person with the same question can see them too.

No questions have been published for this product yet. You can be the first to ask.

Ask a question about this product

Your email address will not be published. Questions are reviewed by our technical team and published together with the answer.

Delivery

Across Türkiye · 1–3 business days

Products in stock ship free anywhere in Türkiye and arrive within 1–3 business days. Items not in stock are supplied to order — the lead time is confirmed to you when the order is approved.

Installation and commissioning

Installation is a service · plumbing is the customer’s responsibility

The system is delivered ready to install; it only needs to be connected to the inlet and outlet lines. If valve setup is required, we provide free support over a video call. Installation and commissioning fall under our service work and are subject to a service fee. Plumbing labour and any pipes, valves and fittings are not included in the price; these items are the customer’s responsibility.

Warranty

2 years · manufacturer

The system is covered by a 2-year manufacturer warranty. During the warranty period, labour and parts are free for faults arising from manufacture or installation. Consumables such as filters, membranes and resin are outside warranty cover — they are replaced when their service life ends; they do not fail.

Withdrawal and returns

Distance sales agreement

The right of withdrawal and the return terms are set out in detail in the distance sales agreement. Systems that have been installed and commissioned, and made-to-order products, are outside its scope.

Cancellation and return terms

How can we help?

Two different requests, two different forms.

The two forms ask different things: if we are building a new system we ask about your water and capacity; if your existing system needs service we ask for its brand and a photo.

Not sure? Call us and let’s work it out together: 0850 304 95 25

31,369.85 VAT included · Free shipping
Add to Cart