Industrial Automatic Sand Unit

115,827.12

VAT included · Made to order · Free shipping

Installation is a service · plumbing is the customer’s responsibility

Free Shipping Across Türkiye
Lead Time Confirmed when the order is placed
2-Year Warranty Misuse is not covered.
Order by Phone 0850 304 95 25
SKU
WP-KS-007
Category
, ,

Which capacity is enough for you? Let us find the unit that suits you best in six questions.

Industrial · Sand Filter · Automatic

Sediment and Turbidity Treatment with the Industrial Automatic Sand Unit

The Industrial Automatic Sand Unit is a high-capacity filtration system that captures suspended solids, turbidity, coarse sediment, silt and rust from water; it cleans itself by automatic backwash and forms the critical first stage that extends the life of everything downstream on the treatment line.

Filter Bed
Quartz Sand
Operation
Automatic Backwash
Position
First Treatment Stage

01Problem & Solution

Coarse Contamination Wears the System Down

Problem

Sediment, Silt and Turbidity

Sand, silt, rust and suspended solids in well, mains or tank water cloud the water, block plumbing and rapidly wear down the carbon, resin and membrane systems downstream, shortening their life.

Solution

High-Capacity Sand Filtration

The Industrial Automatic Sand Unit clears the water by capturing coarse contamination in a sand bed. It cleans itself by automatic backwash and forms the first line of defence on the treatment line.

02Key Features

Strong Filtration, No Effort

The Industrial Automatic Sand Unit is designed for uninterrupted, low-maintenance filtration in high-flow plants.

Sediment and Silt Removal

Capturing sand, silt, rust and coarse sediment leaves the water visibly clearer.

Turbidity Removal

Removing suspended solids and turbidity markedly improves the quality of the water.

Automatic Backwash

At set intervals it backwashes itself, flushing the contamination collected in the bed to drain and refreshing it.

Chemical-Free Cleaning

No extra chemicals are needed for backwashing; the system cleans itself with water alone, keeping running costs low.

System Protection

It protects the activated carbon, softening and membrane systems downstream from coarse contamination and extends their life.

A Long-Lasting Bed

With regular backwashing, the quartz sand bed works efficiently for a long time and rarely needs renewing.

03Technical Specifications

System Details

FeatureValueWhat it does
Unit TypeIndustrial Sand FilterWhere it is installed and how it produces water. An under-counter domestic unit and a commercial one do not run on the same line.
Filter BedQuartz SandThe treatment media in the vessel. This is the bed the water passes through.
ValveAutomatic (Timer/Flow)The part that directs the water and runs the backwash. This is the brain of the system.
CleaningBackwash (Chemical-Free)How the unit cleans itself. Backwashing renews the filter without chemicals.
Contamination CapturedSediment · Silt · RustWhat it removes from the water. It should match your water analysis.
Vessel / CapacityTo ProjectTreated water held in reserve. A large tank means water without waiting when you open the tap.

04Applications

Where Is It Used?

The Industrial Automatic Sand Unit is ideal for high-capacity plants that need sediment-laden, cloudy water treated.

  • Well Water Systems
  • Factories
  • Hotels & Housing Estates
  • Hospitals
  • RO Pre-Treatment
  • Central Water Lines
  • Greenhouse & Agricultural Irrigation
  • Industrial Process Water

05How It Works

How Does the Industrial Automatic Sand Unit Work?

  1. Water Enters the Bed

    Raw water is directed into the quartz sand bed inside the vessel and begins to travel downwards through it.

  2. Mechanical Filtration

    The spaces between the sand grains physically capture sand, silt, rust and suspended solids.

  3. Clear Water Out

    Cleared of turbidity, the water leaves the unit’s outlet for the next treatment stage or the line.

  4. Automatic Backwash

    At the set interval the valve reverses the flow, flushing the sediment and silt collected in the bed to drain.

  5. Return to Service

    When the wash is complete the unit returns automatically to service and filtration continues without interruption.

06Making the Right Choice

What Decides the Right Unit

When choosing the Industrial Automatic Sand Unit, flow rate, contamination load and valve type must be assessed correctly.

Hourly Flow Rate

The plant’s hourly flow rate directly determines vessel size and the quantity of sand needed.

Contamination Load

The turbidity, sediment and rust levels in the water affect the bed configuration and how often it backwashes.

Valve Type

Whether it is time-controlled or flow-controlled is chosen according to usage pattern and water economy.

Drain Availability

A suitable drain line must be available to discharge the backwash water.

07Maintenance and Use

Notes That Keep It Performing

  • The automatic backwash must run regularly, and the drain line and valve settings should be checked periodically.
  • Where the contamination load is heavy the backwash frequency should be increased, or the bed will block over time.
  • The pressure differential between inlet and outlet should be monitored; a marked drop can point to blockage in the bed.
  • Installation and commissioning are best carried out by a technical service engineer; it matters for correct flow and valve settings.

08Frequently Asked Questions

Common Questions

What does the Industrial Automatic Sand Unit do?
It treats water by capturing suspended solids, turbidity, coarse sediment, silt and rust in a sand bed. It cleans itself by automatic backwash and forms the first stage that protects everything downstream on the treatment line.
Does it remove limescale or chlorine?
No. A sand unit captures only physical, coarse contamination. Chlorine and odour call for activated carbon, hardness for water softening and dissolved salts for a reverse osmosis stage.
How often is the sand changed?
With regular backwashing the quartz sand bed works efficiently for a long time and is renewed far less often than carbon or resin. Its life depends on the contamination load of the incoming water.
Are chemicals needed for backwashing?
No. The system uses water alone to clean itself and needs no extra chemicals or consumables. That keeps running costs down.
Why does it sit at the head of the system?
Coarse sediment and silt quickly block an activated carbon bed, softening resin and a reverse osmosis membrane. By capturing that contamination at the front, the sand unit preserves the efficiency and life of the whole system.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Questions & Answers

Questions asked about this product

Questions on compatibility, capacity and installation are answered by our technical team. The answers stay public — so the next person with the same question can see them too.

No questions have been published for this product yet. You can be the first to ask.

Ask a question about this product

Your email address will not be published. Questions are reviewed by our technical team and published together with the answer.

Delivery

Across Türkiye · 1–3 business days

Products in stock ship free anywhere in Türkiye and arrive within 1–3 business days. Items not in stock are supplied to order — the lead time is confirmed to you when the order is approved.

Installation and commissioning

Installation is a service · plumbing is the customer’s responsibility

The system is delivered ready to install; it only needs to be connected to the inlet and outlet lines. If valve setup is required, we provide free support over a video call. Installation and commissioning fall under our service work and are subject to a service fee. Plumbing labour and any pipes, valves and fittings are not included in the price; these items are the customer’s responsibility.

Warranty

2 years · manufacturer

The system is covered by a 2-year manufacturer warranty. During the warranty period, labour and parts are free for faults arising from manufacture or installation. Consumables such as filters, membranes and resin are outside warranty cover — they are replaced when their service life ends; they do not fail.

Withdrawal and returns

Distance sales agreement

The right of withdrawal and the return terms are set out in detail in the distance sales agreement. Systems that have been installed and commissioned, and made-to-order products, are outside its scope.

Cancellation and return terms

How can we help?

Two different requests, two different forms.

The two forms ask different things: if we are building a new system we ask about your water and capacity; if your existing system needs service we ask for its brand and a photo.

Not sure? Call us and let’s work it out together: 0850 304 95 25

Site Haritası
115,827.12 VAT included · Free shipping
Add to Cart