Pure Water Unit

31,369.85

VAT included · Made to order · Free shipping

Installation is a service · plumbing is the customer’s responsibility

Free Shipping Across Türkiye
Lead Time Confirmed when the order is placed
2-Year Warranty Misuse is not covered.
Order by Phone 0850 304 95 25
SKU
WP-SS-006
Category

Which capacity is enough for you? Let us find the unit that suits you best in six questions.

Deionised · RO + DI System

High-Purity Water Production with the Pure Water Unit – 5 L/h

The Pure Water Unit is a system that removes dissolved salts, minerals, heavy metals and unwanted ions from water through reverse osmosis and deionisation stages. It supplies water with near-zero conductivity for laboratory, medical, pharmaceutical and precision manufacturing processes.

Technology
Reverse Osmosis + Deionization
Conductivity
Near Zero
Capacity
Engineered to Requirement

01Problem & Solution

The Quality of the Water Is the Quality of the Product

Problem

Ions Disrupt the Process

In precision manufacturing and analysis, the dissolved salts and ions in water risk deposits and blockages in equipment, residue in the product and drift in measurements. Ordinary mains water is not pure enough for this work.

Solution

Advanced Treatment, Stage by Stage

After pre-treatment and reverse osmosis, the Pure Water Unit removes the remaining ions with ion exchange resins. The result is water of the purity your processes require, produced consistently.

02Key Features

Pure, Measurable, Engineered to the Project

The Pure Water Unit delivers high purity as measurable, continuous production.

RO + DI Stages

Reverse osmosis and deionisation working together produce water of very high purity.

Ion Exchange Resin

Cation and anion resins capture the ions remaining after RO and purify the water.

Conductivity Monitoring

The meter shows the purity of the water in real time and makes the maintenance point clear.

Pre-Treatment Stages

Sediment and carbon filters protect the membrane from chlorine and particles, extending its life.

Capacity to Requirement

With different capacities and technologies, it is engineered for anything from a small business to a plant.

Easy Resin Changes

The resin column is renewed easily, keeping maintenance short and predictable.

Product Video

Take a Closer Look at the System

YouTube video

03Technical Specifications

System Details

FeatureValueWhat it does
System TypePure Water (Deionised) SystemThe main problem the system solves. Pick the wrong type and the water does not improve.
TechnologyReverse Osmosis + DeionizationThe treatment technology used. Reverse osmosis takes out salts and heavy metals; carbon takes out taste and odour.
Pre-TreatmentSediment + Carbon Filter
PurificationIon Exchange ResinThe treatment process applied.
MonitoringConductivity MeterThe user panel. Filter life and fault warnings are read here.
UseLab / Medical / IndustryWhat setting it was designed for. A domestic unit will not carry a commercial load.
Weight15 kgProduct weight. For wall mounting, the supporting surface is chosen accordingly.
Dimensions35 × 30 × 40 cmThe outer dimensions of the unit. The cabinet or plant room has to be wider than this.

04Applications

Where Is It Used?

The Pure Water Unit is used in technical and industrial settings that require high-purity water.

  • Laboratories
  • Pharmaceutical & Medical Manufacturing
  • Electronics Manufacturing
  • The Cosmetics Industry
  • Chemical & Process Industry
  • Glass & Surface Washing
  • Boiler Feed Water
  • R&D & Analysis Centres

05How It Works

How Does the Pure Water Unit Work?

  1. Pre-Treatment

    Raw water passes through sediment and carbon filters, which clear it of particles and chlorine and protect the membrane.

  2. Fed to the Membrane Under Pressure

    The high-pressure pump directs the water onto the semi-permeable membrane.

  3. Reverse Osmosis Separation

    The membrane separates the great majority of dissolved salts, heavy metals and ionic contaminants from the water.

  4. Deionisation

    Ion exchange resins capture the cations and anions remaining after RO and purify the water.

  5. Pure Water Is Drawn Off & Monitored

    The pure water produced goes into a tank or straight to the process, monitored continuously on the conductivity meter.

06Making the Right Choice

What Decides the Right System

When choosing the Pure Water Unit, the purity target, the capacity and the feed water should be assessed.

Purity Target

The conductivity level your application requires determines the choice of stages and resin.

Daily Capacity

Daily pure water consumption determines the membrane and resin volume and the size of the system.

Feed Water Analysis

The hardness and TDS of the raw water affect the pre-treatment required and the life of the resin.

Continuity & Space

The need for uninterrupted production and the placement of the tank and unit should be planned in advance.

07Maintenance and Use

Notes That Preserve Purity

  • The conductivity reading should be monitored regularly; when it starts to rise, the resin has become saturated.
  • The resins should generally be renewed every 6-12 months, depending on water quality and use.
  • Servicing the pre-filter and the membrane on time preserves resin life and the consistency of the purity.
  • Pure water contains no minerals; it is for technical use and is not recommended for drinking.

08Frequently Asked Questions

Common Questions

What does the Pure Water Unit do?
It removes the dissolved salts, minerals, heavy metals and unwanted ions in water through advanced treatment stages, producing water with near-zero conductivity for laboratory, medical, pharmaceutical and precision manufacturing processes.
How does it differ from a reverse osmosis system?
Reverse osmosis treats water under pressure and lowers conductivity substantially. A pure water unit adds deionisation to that and removes the remaining ions as well; together they reach far higher purity.
What capacity should be chosen?
Capacity is determined by daily pure water consumption, the purity target and the raw water analysis. Systems can be engineered at capacities from small businesses to industrial plants.
Can pure water be drunk?
Because pure water contains no minerals it is not recommended for drinking. It is used in technical, industrial and precision manufacturing processes.
When is the resin changed?
When the conductivity reading starts to rise, the resin has become saturated. Depending on use and water quality, renewing it every 6-12 months is generally recommended.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Questions & Answers

Questions asked about this product

Questions on compatibility, capacity and installation are answered by our technical team. The answers stay public — so the next person with the same question can see them too.

No questions have been published for this product yet. You can be the first to ask.

Ask a question about this product

Your email address will not be published. Questions are reviewed by our technical team and published together with the answer.

Delivery

Confirmed when the order is placed

This product is not held in stock; it is supplied to order and the lead time is confirmed to you when the order is approved. Shipping is free anywhere in Türkiye.

Installation and commissioning

Installation is a service · plumbing is the customer’s responsibility

The system is delivered ready to install; it only needs to be connected to the inlet and outlet lines. If valve setup is required, we provide free support over a video call. Installation and commissioning fall under our service work and are subject to a service fee. Plumbing labour and any pipes, valves and fittings are not included in the price; these items are the customer’s responsibility.

Warranty

2 years · manufacturer

The system is covered by a 2-year manufacturer warranty. During the warranty period, labour and parts are free for faults arising from manufacture or installation. Consumables such as filters, membranes and resin are outside warranty cover — they are replaced when their service life ends; they do not fail.

Withdrawal and returns

Distance sales agreement

The right of withdrawal and the return terms are set out in detail in the distance sales agreement. Systems that have been installed and commissioned, and made-to-order products, are outside its scope.

Cancellation and return terms

How can we help?

Two different requests, two different forms.

The two forms ask different things: if we are building a new system we ask about your water and capacity; if your existing system needs service we ask for its brand and a photo.

Not sure? Call us and let’s work it out together: 0850 304 95 25

31,369.85 VAT included · Free shipping